TU‐B‐201B‐01: Radiation Dose Reduction in Medical X‐Ray CT Using Equally‐Sloped Tomography
Author(s) -
Zhao Y,
Fahimian B,
Fung R,
Mao Y,
McNittGray M,
DeMarco J,
Miao J
Publication year - 2010
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.3469197
Subject(s) - imaging phantom , image quality , iterative reconstruction , scanner , nuclear medicine , image resolution , reconstruction algorithm , tomography , radon transform , noise reduction , optics , contrast to noise ratio , reduction (mathematics) , medical imaging , materials science , physics , mathematics , medicine , computer science , artificial intelligence , image (mathematics) , geometry , acoustics
Purpose : An exact Fourier‐based iterative reconstruction technique termed Equally‐Sloped Tomography (EST) has recently been developed to allow a reduction of radiation dose while maintaining image quality. Here we optimize this technique by incorporating a Gradient Descent algorithm with mathematical regularization constraints, including the Non‐Local Means Total Variation model. Using this technique, we conducted a series of comparative experiments to quantify the image quality, and explore radiation dose reduction in CT through reduction of X‐ray flux. Method and Materials : A standard quality control phantom containing multiple contrast visibility and resolution inserts was imaged using a Siemens Somatom Sensation 64 scanner. The X‐ray flux was systematically lowered from 583mAs to 39mAs. All scans were performed under axial mode with constant tube current. Comparison reconstructions were produced by Filtered‐Back Projection (FBP) with a standard uncropped ramp filter. The resolution, signal‐to‐noise ratio (SNR) and contrast‐to‐noise ratio (CNR) were measured and compared as a function of flux. Results : Compared to the FBP reconstruction of 500mAs, the optimized EST reconstruction of 50mAs has comparable SNRs and CNRs. The low‐contrast regions of the phantom exhibit similar visibility. In addition, no resolution degradation is observed in the low‐dose EST reconstruction. Conclusion : As radiation dose is linearly proportional to the X‐ray flux, our results indicate that the optimized EST technique may potentially reduce the CT dose up to 90%, while producing comparable image resolution, quality and contrast as the full‐dose FBP reconstruction. The reasons that EST allows for significant reduction of the CT dose are because (i) an exact Fourier‐based iterative algorithm is used in the reconstruction where both physical and mathematical constraints can be naturally incorporated, (ii) the algorithm is guided towards a lowest‐possible noisy state, which is also strictly consistent with the measured data. Conflict of Interest : Research sponsored by UC Discovery / TomoSoft Technologies Grant #ITL07‐10166.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom