TH‐C‐T‐6E‐10: The Impact of Calculation Grid Size On the Accuracy of IMRT Dose Distribution
Author(s) -
Chung H,
Jin H,
Liu C,
Palta J,
Suh T,
Kim S
Publication year - 2005
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.1998686
Subject(s) - imaging phantom , dosimetry , nuclear medicine , histogram , head and neck , grid , materials science , mathematics , physics , medicine , computer science , geometry , surgery , artificial intelligence , image (mathematics)
Purpose: To experimentally investigate the accuracy of complex IMRT dose distribution with varying dose grid size. Method and Materials: A Head and Neck compression film phantom was constructed from two semi‐hemisphere solid water slabs. Two hypothetical Head and Neck IMRT treatment plans for a 54Gy prescribed dose to a shallow and a deep targets were generated using Philips Pinnacle 3 TPS with 1.5, 2, 3, and 4 mm dose computation grid sizes. Radiochromic films were used for dosimetry. The plans were evaluated by computing the dose cumulative histograms. The 1.5 mm grid size plan was used as a benchmark for plan evaluation. Results: Dose differences between 2 mm and 1.5 mm grid size calculations were within 120 cGy (2.2% of prescribed dose) for shallow target and 132 cGy (2.4%) for deep target respectively over 95% of the area of analysis. The dose differences were 273 cGy (5.1%) and 253 cGy (4.7%) for the 4 mm grid size. In gamma function tests, all grid sizes met the criteria of acceptability (i.e., 95% of the region resulted in gamma index less or equal to 1 with a 3% dose difference and a 3 mm DTA criteria) except for deep target and 3 and 4 mm grid sizes. It was observed that larger grid spacing produces higher dose gradient, which contributes to the failure of the gamma test. The analyses of surface dose histograms showed a general trend of larger grid size producing broader histogram for surface dose. All grid spacing overestimate surface dose. Conclusion: Overall, the effect of varying grid size on dose variation appears to be insignificant as long as the grid size is less than 4 mm. However, 2 mm is recommended to ensure acceptable dose calculations, especially in high gradient regions.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom