z-logo
Premium
SU‐FF‐T‐40: Monte Carlo Calculation of Pd‐103 Prostate Implant Treatment Plan
Author(s) -
Napolitano M,
Butler W
Publication year - 2005
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.1997711
Subject(s) - monte carlo method , dosimetry , radiation treatment planning , nist , nuclear medicine , kerma , computational physics , brachytherapy , physics , mathematics , medicine , computer science , statistics , radiation therapy , surgery , natural language processing
Purpose: A103 Pd TheraSeed® Model 200 prostate implant treatment plan calculation based on TG‐43 formalism will be compared to a Monte Carlo (MCNPX) simulation of the treatment plan complete with detailed seed geometry. Dose contour lines as well as specific dose points will be compared. Method and Materials: Co‐ordinates from typical pre‐plan treatment plans were used to set up 3‐D Monte Carlo simulations of a small prostate (84 seeds) and a medium prostate (107 seeds). The seeds were modeled in full geometric detail and placed in a 50 cm sphere of water. The Model 200 seed geometry was previously benchmarked in a single seed configuration against published TG‐43 dosimetry parameters. Surface Crossing Tallies and Energy Deposition Tallies were used to calculate dose at specific points for comparison to dose points calculated in treatment planning software. Mesh tallies were used to create isodose lines for comparison to those calculated by the TG‐43 based treatment planning software. MCNPX flux values were converted to absolute dose based on NIST measured Air Kerma Strength and NIST measured contained activity measurements of TheraSeed® Model 200. Results: Comparison of the 75, 100, 110, 150, and 200% isodose lines for a series of planes within the treatment area yielded reasonable agreement. As expected some variation from the treatment planning software isodose lines is seen due to attenuation from surrounding seeds as well as differences in the dose distribution surrounding the seeds. Selected dose points along the urethra yielded dose values with a maximum deviation of 20% between the treatment planning software and Monte Carlo calculation. Conclusion: Full three dimensional Monte Carlo modeling of a typical treatment plan is possible in order to make dose comparisons to TG‐43 based formalism calculations for a typical treatment plan configuration. Conflict of Interest: Corresponding author is an employee of Theragenics Corporation®.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here