Premium
SPLENIC SEQUESTRATION SCINTIGRAPHY IN THE DOG: A COMPARISON OF DENATURING TECHNIQUES
Author(s) -
Berry Clifford R.,
Kuperus John H.,
Malone Daniel
Publication year - 1995
Publication title -
veterinary radiology and ultrasound
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.541
H-Index - 60
eISSN - 1740-8261
pISSN - 1058-8183
DOI - 10.1111/j.1740-8261.1995.tb00213.x
Subject(s) - medicine , spleen , scintigraphy , nuclear medicine , region of interest , technetium , technetium 99m , radiology
Five mixed‐breed dogs underwent splenic sequestration scintigraphy following intravenous injection of 647.5 to 740 MBq (17.5–20 mCi) of 99m Technetium labeled autologous red blood cells (RBCs) that had been chemically denatured using two μg of stannous chloride. Left lateral dynamic images were obtained for 20 minutes after injection. Regions of interest (ROI) were drawn around the splenic body and ventral extremity, ventral liver and caudal abdominal great vessels and time activity curves created. Count density information was obtained and uptake ratios were calculated for the spleen ROI/vessel ROI, liver ROI/vessel ROI and spleen ROI/liver ROI at 1, 2.5, 5, 10, 15 and 20 minutes after injection. Two additional studies using different RBC denaturing procedures were done in four of the five dogs. In the second study, the stannous chloride level was doubled to 4.0 μg, while in the third study, the RBCs were denatured by addition of 2.0 μg of stannous chloride and heating at 49°C for 15 minutes. Progressive splenic uptake of denatured RBCs was seen in all dogs during the first 15 to 20 minutes of each study, no matter which denaturing technique was utilized. Significant increases in the spleen ROI:/vessel ROI and spleen ROI:liver ROI ratios were obtained at 5, 10, 15 and 20 minutes when compared to the 1 minute values for each of the labeling techniques. A significant difference was not identified between the three ratios at 15 minutes between the three labeling techniques. There was a trend of increasing values for each ratio where 2.0 μg of stannous chloride technique being the lowest, 4.0 μg of stannous chloride having an intermediate value and the heated technique had the highest values. The heating technique resulted in higher liver activity and increased variability of the mean liver ROI/vessel ROI ratios at all times (1, 2.5, 5,10, and 15 minutes). Using a non‐linear least squares regression analysis, a double exponential equation fit the spleen ROI/vessel ROI and spleen ROI/liver ROI ratios for all three labeling techniques. Imaging of the spleen using all three techniques was acceptable, and a persistent blood pool image would allow for vascular imaging and cardiac gated studies 30 minutes after injection of the denatured, labeled autologous red blood cells. Veterinary Radiology & Ultrasound, Vol. 36, No. I, 1995, pp 57–63 .