z-logo
Premium
Particulate contamination in spinal analgesia
Author(s) -
Eriksen S.
Publication year - 1988
Publication title -
acta anaesthesiologica scandinavica
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.738
H-Index - 107
eISSN - 1399-6576
pISSN - 0001-5172
DOI - 10.1111/j.1399-6576.1988.tb02783.x
Subject(s) - medicine , syringe , vial , contamination , particulates , perforation , surgery , anesthesia , ampoule , chromatography , composite material , ecology , chemistry , materials science , psychiatry , punching , biology
A microscopic investigation was undertaken to quantify the amount of particulate contamination in the injectates of bupivacaine 0.5% in spinal analgesia. No differences were found between samples prepared with either a glass syringe or a disposable plastic syringe, nor could differences be documented between groups where atraumatic opening of vials, perforation of vial stoppers or opening of glass ampoules was performed. The use of commercially available bacterial filters was followed by a significant increase in the amount of particulate contamination, probably filter debris. The clinical use of such filters in spinal analgesia is therefore questionable.