A New Method of Arterial Blood Sampling
Author(s) -
Beck O.,
BechJansen P.,
Rosen J.
Publication year - 1972
Publication title -
acta anaesthesiologica scandinavica
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.738
H-Index - 107
eISSN - 1399-6576
pISSN - 0001-5172
DOI - 10.1111/j.1399-6576.1972.tb00565.x
Subject(s) - medicine , hematoma , gynecology , surgery
A new method of arterial blood sampling from the radial artery using a 1 ml plastic syringe is reported. The results of Pa o2 , Pa co2 and pH analyses of such samples are compared with those from analyses of conventional samples withdrawn into 10 ml glass syringes. It is concluded that the results of analyses of editorial samples by the new mehtod and fully accaptable for clinical use. The only complication experienced was the formation of a small haematoma in a few cases. ZUSAMMENFASSUNG Es wird über eine neue Methode der Blutabnahme aus der Arteria radialis mit einer 1 ml‐Plastik‐spritze berichtet. Die Ergebnisse der Pa o2‐ , Pa co2 ‐und pH‐Bestimmungen aus solchen Blutproben wurden mit denen konventioneller Blutproben, die mittels 10 ml Glasspritzen gewonnen worden waren, verglichen. Dabei kamen wir zu dem Schluβ, daβ die Analysenresultate der mit der neuen Methode gewonnenen arteriellen Blutproben für den klinischen Bedarf annehmbar sind. Die einzige festgestellte Komplikation war die Ausbildung kleiner ämatome in einigen Föllen.