Premium
Impact of Pump Replacement on Outcome in Advanced Heart Failure Patients With Left Ventricular Assist System
Author(s) -
Iwashima Yoshio,
Yanase Masanobu,
Horio Takeshi,
Seguchi Osamu,
Murata Yoshihiro,
Fujita Tomoyuki,
Toda Koichi,
Kawano Yuhei,
Nakatani Takeshi
Publication year - 2013
Publication title -
artificial organs
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.684
H-Index - 76
eISSN - 1525-1594
pISSN - 0160-564X
DOI - 10.1111/aor.12045
Subject(s) - heart failure , cardiology , ventricular assist device , medicine
Pump thrombosis is one of the major adverse events associated with the use of a left ventricular assist system ( LVAS ) in patients with advanced heart failure. We investigated the clinical implication of pump replacement because of thrombus formation. This study included 87 patients who underwent implantation of a N ipro ( T oyobo) pulsatile extracorporeal LVAS intended as a bridge to transplantation and were alive more than 3 months after implantation. The pump of this device is translucent, and daily evaluation for signs of thrombus formation was performed. Pump replacement was performed for significant thrombus formation that became visible. Data collection including demographics as well as hematologic values were performed 1 day before (baseline) and 3 months after implantation, and all patients were followed for 2 years or until death. At 3 months after LVAS implantation, 41 patients (47.1%) had undergone pump replacement because of pump thrombus. Baseline body surface area <1.63 m 2 was a significant predictor of pump replacement (hazard ratio [ HR ] 2.15, P = 0.04). At 3 months after implantation, there was a significantly higher incidence of stroke ( P < 0.05) as well as a significantly greater decrease in body weight ( F = 4.92, P = 0.03) in patients who underwent pump replacement as compared to those without. The 2‐year mortality after implantation was 26.4%. Multivariate C ox regression analysis showed that pump replacement within 3 months after implantation was an independent predictor of mortality ( HR 2.50, P = 0.03). In conclusion, pump replacement for thrombus formation may have a strong association with worse outcome. Our results reconfirm the clinical importance of device thrombus in the management of LVAS .
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom