Detective quantum efficiency, modulation transfer function and energy resolution comparison between CdTe and silicon sensors bump‐bonded to XPAD3S
Author(s) -
Medjoubi Kadda,
Bucaille Thierry,
Hustache Stéphanie,
Bérar JeanFrançois,
Boudet Nathalie,
Clemens JeanClaude,
Delpierre Pierre,
Dinkespiler Bernard
Publication year - 2010
Publication title -
journal of synchrotron radiation
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.172
H-Index - 99
ISSN - 1600-5775
DOI - 10.1107/s0909049510013257
Subject(s) - physics , optical transfer function , optics , photon , quantum efficiency , silicon , detector , image sensor , optoelectronics , photon energy , photodiode , photon counting , synchrotron , materials science
XPAD3S is a single‐photon‐counting chip developed in collaboration by SOLEIL Synchrotron, the Institut Louis Néel and the Centre de Physique de Particules de Marseille. The circuit, designed in the 0.25 µm IBM technology, contains 9600 square pixels with 130 µm side giving a total size of 1 cm × 1.5 cm. The main features of each pixel are: single threshold adjustable from 4.5 keV up to 35 keV, 2 ms frame rate, 10 7  photons s −1 mm −2 maximum local count rate, and a 12‐bit internal counter with overflow allowing a full 27‐bit dynamic range to be reached. The XPAD3S was hybridized using the flip‐chip technology with both a 500 µm silicon sensor and a 700 µm CdTe sensor with Schottky contacts. Imaging performances of both detectors were evaluated using X‐rays from 6 keV up to 35 keV. The detective quantum efficiency at zero line‐pairs mm −1 for a silicon sensor follows the absorption law whereas for CdTe a strong deficit at low photon energy, produced by an inefficient entrance layer, is measured. The modulation transfer function was evaluated and it was shown that both detectors present an ideal modulation transfer function at 26 keV, limited only by the pixel size. The influence of the Cd and Te K ‐edges of the CdTe sensor was measured and simulated, establishing that fluorescence photons reduce the contrast transfer at the Nyquist frequency from 60% to 40% which remains acceptable. The energy resolution was evaluated at 6% with silicon using 16 keV X‐rays, and 8% with CdTe using 35 keV X‐rays. A 7 cm × 12 cm XPAD3 imager, built with eight silicon modules (seven circuits per module) tiled together, was successfully used for X‐ray diffraction experiments. A first result recently obtained with a new 2 cm × 3 cm CdTe imager is also presented.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom