z-logo
open-access-imgOpen Access
Comparison of the cuff pressure of a TaperGuard endotracheal tube and a cylindrical endotracheal tube after lateral rotation of head during middle ear surgery
Author(s) -
Eunkyung Choi,
Yongmin Park,
Yunseok Jeon
Publication year - 2017
Publication title -
medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.59
H-Index - 148
eISSN - 1536-5964
pISSN - 0025-7974
DOI - 10.1097/md.0000000000006257
Subject(s) - medicine , sore throat , cuff , intubation , anesthesia , endotracheal tube , throat , surgery
Abstract Background: Positional change affects the cuff pressure of an endotracheal tube (ETT) in treacheally intubated patients. We compared the cuff pressure of a TaperGuard ETT and a cylindrical ETT after lateral rotation of head during middle ear surgery. Methods: Fifty-two patients aged 18–70 years underwent a tympanomastoidectomy under general anesthesia were randomly allocated to receive endotracheal intubation with cylindrical (group C, n = 26) or TaperGuard ETTs (group T, n = 26). After endotracheal intubation, the ETT cuff pressure was set at 22 cmH 2 O in the neutral position of head. After lateral rotation of head, the cuff pressure was measured again and readjusted to 22 cmH 2 O. In addition, the change of distance from the carina to the tip of the ETT was measured before and after the positional change. The incidence of cough, sore throat, and hoarseness was assessed at 30 minutes, 6 hours, and 24 hours after surgery. Results: There was no difference in demographic data between groups. After lateral rotation of head, the cuff pressure significantly increased in group T (11.9 ± 2.3 cmH 2 O) compared with group C (6.0 ± 1.9 cmH 2 O) ( P  < 0.001). The incidence of a cuff pressure >30 cmH 2 O was higher in group T (96.2%) than in group C (30.8%) ( P  < 0.001). In addition, the degree of displacement of an ETT was greater in group T (11.0 ± 1.7 mm) than in group C (7.2 ± 2.6 mm) ( P  < 0.001). The overall incidences of postoperative sore throat, hoarseness, and cough at 30 minutes, 6 hours, and 24 hours after surgery were comparable between two groups. Conclusion: The cuff pressure was higher in the TaperGuard ETT than in the cylindrical ETT after positional change of head from neutral to lateral rotation. In addition, after a positional change, the extent of displacement of ETT was greater in the TaperGuard ETT than in the cylindrical ETT.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here