z-logo
open-access-imgOpen Access
Cardiac CT derived 3D reconstruction discriminates for complexity and hemodynamic effect of transcatheter mitral valve repair
Author(s) -
Frank Meijerink,
Iris Wolsink,
Marja Holierook,
E. V. Chekanova,
R. Nils Planken,
Adriënne van Randen,
Rob J. de Winter,
Marcel A.M. Beijk,
K. T. Koch,
Daniëlle RobbersVisser,
S. Matthijs Boekholdt,
Berto J. Bouma,
J. Baan
Publication year - 2021
Publication title -
european heart journal
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 4.336
H-Index - 293
eISSN - 1522-9645
pISSN - 0195-668X
DOI - 10.1093/eurheartj/ehab724.1661
Subject(s) - medicine , fossa ovalis , mitral regurgitation , mitral annulus , cardiology , mitral valve , hemodynamics , nuclear medicine , left atrium , blood pressure , diastole , atrial fibrillation
Background Transcatheter mitral valve repair (TMVR) is increasingly used to treat mitral regurgitation (MR) in high risk patients. Optimal transseptal access and guiding catheter position are essential to perform adequate repair. Anatomy of the inter-atrial septum (IAS) and mitral annulus (MA) are often complex and difficult to determine from echocardiography. Purpose The aim of the current study was to evaluate whether pre-TMVR cardiac CT and 3D reconstruction of the IAS and MA could discriminate for complexity and hemodynamic effect of TMVR. Methods Patients planned for TMVR, underwent cardiac CT scan (if eligible). Post-processing software was used to segment and reconstruct the aortic root, IAS, fossa ovalis (FO) and MA, resulting in a 3D model. The following parameters were measured in each model: (1) IAS angle (°) (2) Posterior-FO angle (°) (3) FO-perpendicularity angle (°) (4) MA area (cm2). Patient specific anatomy was categorized in 4 groups as either (1) Posterior-perpendicular (PP) FO + limited IAS angle, (2) PP FO + wide IAS angle, (3) non-PP FO + limited IAS angle or (4) non-PP FO + wide IAS angle. PP FO was defined as posterior-FO angle >65° and FO-perpendicularity angle >135°. IAS angle was considered limited if <110°. Device implantation time (min) was used to assess complexity of the procedure and was compared between the different groups. MR reduction (grades), number of clips used and mitral valve (MV) gradient (mmHg) were compared for patients with MA area <14 cm2 vs. ≥14 cm2. Results 46 patients (mean age 75 years, 41% male) were included. Anatomy was classified (1) PP FO + limited IAS angle in 13, (2) PP FO + wide IAS angle in 13, (3) Non-PP FO + limited IAS angle in 8 and (4) Non-PP FO + wide IAS angle in 12. Median device implantation time was 20 min in group 1, compared to 39 min in group 2 (p=0.02), 33 min in group 3 (p=0.03) and 29 min in group 4 (p=0.08). In patients with MA area <14 cm2, MR reduction was greater (2.22 vs. 1.68, p=0.02), number of clips used was lower (1.44 vs. 1.79, p=0.05) and MV gradient was higher, though not significant (3.15 vs. 2.58, p=0.26) Conclusion The current study showed that TMVR seemed less complex in patients with an optimal anatomy. In patients with limited mitral annulus area a more favorable hemodynamic effect was achieved. Cardiac CT and 3D reconstruction could therefore be of strong aid for procedural planning of TMVR. Funding Acknowledgement Type of funding sources: Private grant(s) and/or Sponsorship. Main funding source(s): Abbott Vascular Anatomy and device implantation timeHemodynamic effect of annulus area

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom