Premium
In vivo magnetic resonance spectroscopy detection of combined glutamate‐glutamine in healthy upper cervical cord at 3 T
Author(s) -
Solanky Bhavana S,
AbdelAziz Khaled,
Yiannakas Marios C,
Berry Alaine M,
Ciccarelli Olga,
WheelerKingshott Claudia AM
Publication year - 2013
Publication title -
nmr in biomedicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.278
H-Index - 114
eISSN - 1099-1492
pISSN - 0952-3480
DOI - 10.1002/nbm.2867
Subject(s) - glutamine , spinal cord , in vivo , in vivo magnetic resonance spectroscopy , nuclear magnetic resonance , magnetic resonance imaging , ex vivo , glutamate receptor , spectroscopy , chemistry , cord , nuclear medicine , biomedical engineering , medicine , biology , radiology , surgery , amino acid , biochemistry , physics , receptor , microbiology and biotechnology , quantum mechanics , psychiatry
The possibility of quantifying the superimposed signal of glutamate and glutamine (Glx) and its components by 1 H magnetic resonance spectroscopy (MRS) in the spinal cord is an exciting challenge with important clinical applications in neurological conditions. The spinal cord is a particularly difficult region of interest due to its small volume, magnetic field inhomogeneities and physiological motion. In this study, we investigated for the first time the feasibility of obtaining quantitative measurements of Glx in healthy cervical spinal cord by 1 H MRS at 3 T. The aim of this study was to compare two commercially available MRS sequences by spectral simulations and in vivo . A short echo time (TE) point resolved spectroscopy (PRESS) with TE = 30 ms and a stimulated echo acquisition mode (STEAM) with TE = 11 ms and mixing time (TM) = 17 ms were compared for reliability of Glx fit. Data allowed us to determine sample size estimates for future clinical studies for the first time. Results showed that PRESS provided a reliable fit for Glx in all cases (Cramér Rao lower bounds < 20%) whereas no reliable Glx fits were achieved using STEAM. Neither protocol provided reliable Glu quantification. The power calculations showed that a minimum sample size of 17 subjects per group was needed to detect Glx changes of > 20% using the PRESS sequence. This study proposed a clinically feasible MRS method for Glx detection in the human cervical cord in vivo including sample sizes needed for conclusive clinical studies. Copyright © 2012 John Wiley & Sons, Ltd.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom