Premium
Improving the detection specificity of endogenous MRI for reactive oxygen species (ROS)
Author(s) -
Tain RongWen,
Scotti Alessandro M.,
Cai Kejia
Publication year - 2019
Publication title -
journal of magnetic resonance imaging
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.563
H-Index - 160
eISSN - 1522-2586
pISSN - 1053-1807
DOI - 10.1002/jmri.26629
Subject(s) - reactive oxygen species , ex vivo , imaging phantom , nuclear medicine , endogeny , medicine , chemistry , nuclear magnetic resonance , biochemistry , in vitro , physics
Background The detection of tissue reactive oxygen species (ROS) using endogenous MRI methods has great potential applications in research and the clinic. We recently demonstrated that ROS produce a significant T 1 ‐shortening effect. However, T 1 or T 1 ‐weighted contrast is not specific, as there are many other factors that alter tissue T 1 . Purpose To investigate whether the presence of ROS alters tissue environmental conditions such as the proton exchange rate ( K ex ) to improve the detection specificity of endogenous ROS MRI. Study Type Prospective. Subjects/Phantom The ROS‐producing phantoms consisted of fresh egg white treated with H 2 O 2 and healthy mice injected with pro‐oxidative rotenone. Field Strength/Sequence T 1 mapping was performed based on fast spin‐echo sequence and K ex was evaluated using chemical exchange saturation transfer (CEST) MRI with varied saturation power (QUESP) on a 9.4 T animal scanner. Assessment Phantom experiments were conducted to evaluate the overall K ex of CEST‐expressing metabolites in fresh egg white treated with H 2 O 2 of various concentrations (0, 0.025, 0.05, 0.1, and 0.25 v/v%). The egg white phantom continuously produced ROS for more than 3 hours. Various experiments were performed to rule out potential contributing factors to the observed K ex changes. In addition, in vivo MRI study was conducted with a well‐established rotenone‐exposed mouse model. Statistical Tests Student's t ‐test. Results Egg white phantoms treated with H 2 O 2 of various concentrations showed a 26–85% increase in K ex compared with controls. In addition, the K ex of egg white is negligibly affected by other potential confounding factors, including paramagnetic contrast agents (<11%), oxygen (2.3%), and iron oxidation (<10%). Changes in temperature (<1°C) and pH (ΔpH <0.1) in H 2 O 2 ‐treated egg white were also negligible. Results from the in vivo rotenone study were consistent with the phantom studies by showing reduced T 1 relaxation time (6%) and increased K ex (9%) in rotenone‐treated mice. Data Conclusion We demonstrate that the specificity of endogenous ROS MRI can be improved with the aid of proton exchange rate mapping. Level of Evidence : 2 Technical Efficacy Stage : 2 J. Magn. Reson. Imaging 2019;50:583–591.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom