Quantitative BOLD: The effect of diffusion
Author(s) -
Dickson John D.,
Ash Tom W.J.,
Williams Guy B.,
Harding Sally G.,
Carpenter T. Adrian,
Me David K.,
Ansorge Richard E.
Publication year - 2010
Publication title -
journal of magnetic resonance imaging
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.563
H-Index - 160
eISSN - 1522-2586
pISSN - 1053-1807
DOI - 10.1002/jmri.22151
Subject(s) - monte carlo method , signal (programming language) , data acquisition , computer science , diffusion , noise (video) , sampling (signal processing) , nuclear magnetic resonance , physics , artificial intelligence , computer vision , mathematics , image (mathematics) , statistics , filter (signal processing) , thermodynamics , programming language , operating system
Purpose: To make the quantitative blood oxygenation level‐dependent (qBOLD) method more suitable for clinical application by accounting for proton diffusion and reducing acquisition times. Materials and Methods: Monte Carlo methods are used to simulate the signal from diffusing protons in the presence of a blood vessel network. A diffusive qBOLD model was then constructed using a lookup table of the results. Acquisition times are reduced by parallel imaging and by employing an integrated fieldmapping method, rather than running an additional sequence. Results: The addition of diffusion to the model is shown to have a significant impact on predicted signal formation. This is found to affect all fitted parameters when the model is applied to real data. Parallel imaging and integrated fieldmapping allowed the GESSE (gradient echo sampling of a spin echo) acquisition to be made in less than 10 minutes while maintaining high signal‐to‐noise ratio (SNR). Conclusion: By incorporating integrated field mapping and parallel imaging techniques, GESSE data were acquired within clinically acceptable acquisition times. These data fit closely to the diffusive qBOLD model, providing more realistic and robust measurements of T 2 and blood oxygenation than the static model. J. Magn. Reson. Imaging 2010;32:953–961. © 2010 Wiley‐Liss, Inc.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom