Premium
First North American experience with the transfemoral ACURATE‐ neo TM self‐expanding transcatheter aortic bioprosthesis
Author(s) -
Bagur Rodrigo,
Teefy Patrick J.,
Kiaii Bob,
Diamantouros Pantelis,
Chu Michael W.A.
Publication year - 2017
Publication title -
catheterization and cardiovascular interventions
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.988
H-Index - 116
eISSN - 1522-726X
pISSN - 1522-1946
DOI - 10.1002/ccd.26802
Subject(s) - medicine , stenosis , cardiac skeleton , cardiology , surgery , aortic valve stenosis , aortic valve , aortic valve replacement
Background: Transcatheter aortic valve implantation (TAVI) has become a therapeutic alternative for patients presenting with severe symptomatic aortic stenosis and considered at high‐surgical risk. Paravalvular leak (PVL), conduction disorders, and coronary obstruction remain unresolved procedure‐related complications. The aim of this manuscript was to report the first North American experience with the ACURATE‐ neo TM aortic bioprosthesis and its ACURATE‐TF TM delivery system (Symetis S.A., Ecublens, Switzerland). Methods: Transfemoral ACURATE‐ neo TM aortic valve implantation was performed in 20 patients. Clinical and echocardiographic assessment was performed at baseline, postprocedure and at least 30 days. Outcomes were assessed according to valvular academic research consortium (VARC‐2) criteria. Results: The mean age was 82.7 ± 7.0 years with a mean logistic‐EuroSCORE‐II of 5.0 ± 2.9% and Society of Thoracic Surgeons score of 4.7 ± 2.3%. Device success was achieved in all patients. The mean distance between the aortic‐annulus and the left main coronary artery ostium was 14.3 ± 3.2 mm, and eight (40%) patients had <12 mm. At 30 days, there were no deaths, conversions to surgery, or major procedure‐related complications. New‐pacemaker implantation was required in one (5.3%) patient. ACURATE‐ neo TM implantation resulted in a significant reduction in mean transvalvular gradient (49.9 ± 15.8 to 9.7 ± 5.7 mm Hg, P < 0.0001) and increase in effective‐orifice area (0.65 ± 0.16 to 1.83 ± 0.36 cm 2 , P = 0.001) at hospital discharge. Paravalvular leak was absent in four (20%) patients, trace in nine (45%) patients, and mild in seven (35%) patients. Hospital discharge occurred at a mean of 7.0 ± 4.5 days, and all patients were in NYHA class I–II at a mean follow‐up of 8.6 ± 2.3 months. Conclusion: The present initial North American experience shows that the ACURATE‐ neo TM aortic bioprosthesis was safely and successfully implanted by transfemoral approach. The special design of this newer‐generation device affords a stable and predictable implantation, while providing optimal hemodynamic performance with a relatively low rate of PPI. © 2016 Wiley Periodicals, Inc.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom