Premium
Annular flow pressure drop model for pease–anthony‐type venturi scrubbers
Author(s) -
Viswanathan S.,
Gnyp A. W.,
St. Pierre C. C.
Publication year - 1985
Publication title -
aiche journal
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.958
H-Index - 167
eISSN - 1547-5905
pISSN - 0001-1541
DOI - 10.1002/aic.690311204
Subject(s) - venturi effect , pressure drop , mechanics , scrubber , flow (mathematics) , two phase flow , drop (telecommunication) , chemistry , volumetric flow rate , materials science , thermodynamics , inlet , mechanical engineering , engineering , physics , organic chemistry
An annular flow pressure drop model has been developed and compared with experimental data obtained on a pilot‐plant‐size Pease‐Anthony‐type venturi scrubber. Droplet and film accelerations as well as wall friction, based on the two‐phase Lockhart‐Martinelli correlation, are considered. Excellent agreement with experimental data is demonstrated for a wide range of throat gas velocities, liquid to gas ratios, and film flow rates for a single scrubber geometry.