
Resection of a peri-acetabular chondrosarcoma and reconstruction of the pelvis. A case report
Author(s) -
H. K. L. Nielsen,
R P Veth,
J Oldhoff,
H. Schraffordt Koops,
John T. Scales
Publication year - 1985
Publication title -
journal of bone and joint surgery. british volume/the journal of bone and joint surgery. british volume
Language(s) - English
Resource type - Journals
eISSN - 0968-7300
pISSN - 0301-620X
DOI - 10.1302/0301-620x.67b3.3997950
Subject(s) - chondrosarcoma , pelvis , medicine , resection , prosthesis , acetabulum , peri , surgery , ischium , femoral head , radiology
We report a patient with a peri-acetabular chondrosarcoma which was treated by resection of part of the pelvis and the femoral head. This was followed by replacement with a custom-made titanium alloy pelvic portion and a conventional total hip prosthesis. The operation was carried out in two stages, and yielded a good functional and cosmetic result.